Lianhe
LIANHE
Industrial Computing

Multi-node servers

APC-9004

APC-9004 Four-Node Rugged Server

Intel Xeon 6

  • Processor4 independent nodes, each with 1 × Intel Xeon 6505P (12 cores / 24 threads; 2.2–4.1 GHz; 48 MB cache; 150 W TDP). System total: 48 cores / 96 threads.
  • Memory128 GB DDR5 ECC RDIMM per node, 512 GB total; up to 6400 MT/s with a validated module population. 256 GB per node (1 TB total) can be specified.
  • Operating systemCustomization options: Windows Server 2025 / 2022, Ubuntu Server LTS, Debian, Red Hat Enterprise Linux, Rocky Linux, AlmaLinux, SUSE Linux Enterprise Server and openSUSE. Windows 11 Pro / Enterprise, Fedora and other x86-64 systems can be evaluated on request. OS edition, kernel, drivers and application compatibility are confirmed for the selected hardware.
Request a quote ↗Full specifications ↓

DESIGN & CONFIGURATION

Product overview

  • 6U four-node enclosure with independent operating systems
  • Per node: 2 × 10 GbE; management network configured separately.
  • Per node: 1 TB NVMe boot SSD and 4 TB data SSD. Four independently managed storage sets.
  • Project-specific power, connectors and operating environment

TECHNICAL DATA

Reference specifications

Reference configuration. Customizable to your requirements.

Processor4 independent nodes, each with 1 × Intel Xeon 6505P (12 cores / 24 threads; 2.2–4.1 GHz; 48 MB cache; 150 W TDP). System total: 48 cores / 96 threads.
Memory128 GB DDR5 ECC RDIMM per node, 512 GB total; up to 6400 MT/s with a validated module population. 256 GB per node (1 TB total) can be specified.
Operating systemCustomization options: Windows Server 2025 / 2022, Ubuntu Server LTS, Debian, Red Hat Enterprise Linux, Rocky Linux, AlmaLinux, SUSE Linux Enterprise Server and openSUSE. Windows 11 Pro / Enterprise, Fedora and other x86-64 systems can be evaluated on request. OS edition, kernel, drivers and application compatibility are confirmed for the selected hardware.
Form factor6U four-node rack system
System architectureIntel x86-64; custom motherboard, firmware and I/O integration.
StoragePer node: 1 TB NVMe boot SSD and 4 TB data SSD. Four independently managed storage sets.
Storage protectionRAID 0 / 1 / 5 / 10 options with a compatible controller; RAID 5 requires at least 3 drives and RAID 10 at least 4. Usable capacity depends on the selected RAID layout.
Graphics / GPUBMC display controller for local service console; optional discrete graphics subject to expansion space and power budget.
NetworkingPer node: 2 × 10 GbE; management network configured separately.
I/O connectionsUSB 3.x service ports, VGA console and RS-232 interfaces; standard connectors or locking circular connectors can be specified. Connector pinout and quantity are defined for each project.
ExpansionPCIe 5.0 host platform; riser layout, slot count and electrical lane allocation are matched to the enclosure, storage controller and network adapters.
ManagementIndependent OS instances and power control for four nodes; optional per-node BMC, remote console and monitoring.
Power supplyAC 220 V, 50 Hz reference input; 2000 W nominal supply proposal. Redundant supplies and other AC / DC inputs can be specified. Supply rating is not measured system consumption.
CoolingForced-air cooling with replaceable fan assemblies; airflow and component power limits are engineered for the installation.
EnclosureCNC-machined aluminum alloy enclosure; mounting, finish and connector protection can be specified.
Dimensions482.6 × 600 × 266 mm (W × D × H); 6U enclosure reference. Final drawings depend on connectors and mounting hardware.
WeightApprox. 40 kg enclosure-family reference; final weight varies with installed hardware.
Operating environmentTarget operating range: −20°C to +55°C; lower-temperature operation can be engineered on request. The accepted range depends on the complete configured system and environmental testing.
Storage environmentTarget non-operating range: −40°C to +65°C; up to 95% relative humidity, non-condensing. Project-specific qualification applies.
CustomizationCPU, memory, storage, GPU, network adapters, connector layout, power input and environmental test requirements can be specified.

PROJECT REQUIREMENTS

Environmental & EMC testing

For international projects, specify the required test standard, method, severity and acceptance criteria in your inquiry. Potential references include MIL-STD-810 or IEC 60068 for environmental testing, and MIL-STD-461 for equipment EMC testing. Applicability must be reviewed for your application.

Test methods, levels and acceptance criteria are agreed for the configured system. Request applicable reports for your project; listing a standard does not indicate certification.

LET’S DISCUSS YOUR PROJECT

Configure your APC-9004.

Tell us about your application, quantity and configuration requirements. Our sales team will help you plan the next step.

Request a Quote ↗

Open Project Enquiry with this product already selected.

Visit our Alibaba Storefront ↗